DC and AC parameters
M24512-W M24512-R M24512-DR M24512-DF
8
DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device.
Table 6. Operating conditions (voltage range W)
Symbol
Parameter
VCC Supply voltage
TA
Ambient operating temperature
fC
Operating clock frequency
1. For devices identified by process letter K.
Min.
2.5
–40
-
Max.
5.5
85
1(1)
Unit
V
°C
MHz
Table 7. Operating conditions (voltage range R)
Symbol
Parameter
VCC Supply voltage
TA
Ambient operating temperature
fC
Operating clock frequency
1. For devices identified by process letter K.
Min.
1.8
–40
-
Max.
5.5
85
1(1)
Unit
V
°C
MHz
Table 8. Operating conditions (voltage range F)
Symbol
Parameter
VCC Supply voltage
TA
Ambient operating temperature
fC
Operating clock frequency
1. For devices identified by process letter K.
Min.
1.7
–40
-
Max.
5.5
85
1(1)
Unit
V
°C
MHz
Table 9. AC measurement conditions
Symbol
Parameter
Cbus
Load capacitance
SCL input rise/fall time, SDA input fall time
Input levels
Input and output timing reference levels
Min.
Max.
100
-
50
0.2 VCC to 0.8 VCC
0.3 VCC to 0.7 VCC
Unit
pF
ns
V
V
24/40
Doc ID 16459 Rev 26