DC and AC parameters
M24512-W M24512-R M24512-DR M24512-DF
Table 15. DC characteristics (M24512-DF, device grade 6)
Symbol
Parameter
Test conditions(1) (in addition
to those in Table 8)
Min.
Max. Unit
ILI
Input leakage current
(E1, E2, SCL, SDA)
VIN = VSS or VCC
device in Standby mode
ILO
Output leakage current
SDA in Hi-Z, external voltage
applied on SDA: VSS or VCC
ICC Supply current (Read)
VCC = 1.7 V, fc= 400 kHz
fc= 1 MHz(3)
-
±2
µA
-
±2
µA
-
0.8(2) mA
-
2.5 mA
ICC Supply current (Read)
ICC0 Supply current (Write)
ICC1 Standby supply current
VIL
Input low voltage
(SCL, SDA, WC)
VCC = 1.6 V, fc= 400 kHz
During tW
Device not selected(5),
VIN = VSS or VCC, VCC = 1.7 V
1.7 V ≤ VCC < 2.5 V
0.8 mA
-
5(4)
mA
-
1
µA
–0.45 0.25 VCC V
Input high voltage
(SCL, SDA)
VIH Input high voltage
(WC, E2, E1, E0)
1.7 V ≤ VCC < 2.5 V
1.7 V ≤ VCC < 2.5 V
0.75 VCC 6.5
V
0.75 VCC VCC+0.6 V
VOL Output low voltage
IOL = 1 mA, VCC = 1.7 V
-
0.2
V
1. If the application uses the voltage range F device with 2.5 V < VCC < 5.5 V and -40 °C < TA < +85 °C,
please refer to Table 13 instead of this table.
2. For devices identified by process letters K: ICC(max) = 1.5 mA.
3. Only for devices identified with process letter K.
4. Characterized value, not tested in production.
5. The device is not selected after power-up, after a Read instruction (after the Stop condition), or after the
completion of the internal write cycle tW (tW is triggered by the correct decoding of a Write instruction).
28/40
Doc ID 16459 Rev 26