Electrical characteristics
Table 37. Ethernet management interface 2 AC timing specifications5
Parameter/Condition
Symbol1
Min
Typ
Max
Unit Notes
3. This parameter is dependent on the Ethernet clock frequency. The delay is equal to 5 Ethernet clock periods ± 3 ns. For
example, with an Ethernet clock of 400 MHz, the min/max delay is 12.5 ns ± 3 ns.
4. tenet_clk is the Ethernet clock period (Frame Manager clock period).
5. For recommended operating conditions, see Table 3.
This figure shows the Ethernet management interface timing diagram
tMDC
MDC
MDIO
(Input)
MDIO
(Output)
tMDCH
tMDDVKH
tMDDXKH
tMDKHDX
Figure 16. Ethernet management interface timing diagram
3.11.4 IEEE 1588 electrical specifications
3.11.4.1 IEEE 1588 DC electrical characteristics
This table shows IEEE 1588 DC electrical characteristics when operating at LVDD = 2.5
V supply.
Table 38. IEEE 1588 DC electrical characteristics (LVDD = 2.5 V)3
Parameters
Symbol
Min
Max
Unit
Input high voltage
VIH
Input low voltage
VIL
Input current (LVIN= 0 V or LVIN= LVDD)
IIH
Output high voltage (LVDD = min, IOH = -1.0 mA)
VOH
1.70
—
-50
2.00
—
V
0.70
V
+50
μA
LVDD + 0.3
V
Table continues on the next page...
Notes
1
1
2
—
QorIQ T2080 Data Sheet, Rev. 3, 03/2018