Enhanced Super I/O Controller with Fast IR
Datasheet
DMA latency without causing a disk error. Table 6.14 gives several examples of the delays with aFIFO.
The data is based upon the following formula:
Threshold # x
1
x 8 - 1.5 µs = DELAY
DATA RATE
At the start of a command, the FIFO action is always disabled and command parameters must be sent
based upon the RQM and DIO bit settings. As the command execution phase is entered, the FIFO is
cleared of any data to ensure that invalid data is not transferred.
An overrun or underrun will terminate the current command and the transfer of data. Disk writes will
complete the current sector by generating a 00 pattern and valid CRC. Reads require the host to remove
the remaining data so that the result phase may be entered.
Table 6.14 - FIFO Service Delay
FIFO THRESHOLD
EXAMPLES
1 byte
2 bytes
8 bytes
15 bytes
MAXIMUM DELAY TO SERVICING AT
2 Mbps* DATA RATE
1 x 4 µs - 1.5 µs = 2.5 µs
2 x 4 µs - 1.5 µs = 6.5 µs
8 x 4 µs - 1.5 µs = 30.5 µs
15 x 4 µs - 1.5 µs = 58.5 µs
FIFO THRESHOLD
EXAMPLES
1 byte
2 bytes
8 bytes
15 bytes
MAXIMUM DELAY TO SERVICING AT
1 Mbps DATA RATE
1 x 8 µs - 1.5 µs = 6.5 µs
2 x 8 µs - 1.5 µs = 14.5 µs
8 x 8 µs - 1.5 µs = 62.5 µs
15 x 8 µs - 1.5 µs = 118.5 µs
Note:
FIFO THRESHOLD
EXAMPLES
1 byte
2 bytes
8 bytes
15 bytes
MAXIMUM DELAY TO SERVICING AT
500 Kbps DATA RATE
1 x 16 µs - 1.5 µs = 14.5 µs
2 x 16 µs - 1.5 µs = 30.5 µs
8 x 16 µs - 1.5 µs = 126.5 µs
15 x 16 µs - 1.5 µs = 238.5 µs
*The 2 Mbps data rate is only available if VCC = 5V.
SMSC FDC37C672
Page 30
DATASHEET
Rev. 10-29-03